| Availability: | |
|---|---|
| Quantity: | |
This oil-free, high-pressure oxygen booster compressor is specifically designed for boosting low-pressure oxygen to 5–25 bar (72.5–362.5 psi) for direct cylinder filling. With a flow range of 20–80 m³/h (0.33–1.33 m³/min) , it is the ideal solution for small to medium-scale oxygen filling stations, medical oxygen systems, and on-site oxygen generation plants.
Built with oxygen-safe materials and 100% oil-free compression, it guarantees pure, contamination-free oxygen output – critical for medical, industrial, and high-purity applications.
Oil‑Free Operation – Delivers 100% pure, contamination‑free oxygen, essential for medical and industrial filling applications.
High‑Pressure Boosting – Pressurizes oxygen from low inlet up to 5–25 bar, meeting cylinder filling requirements directly.
Flexible Flow Range – Flow adjustable from 20 to 80 m³/h, suitable for small to medium‑scale filling stations with variable demand.
Oxygen‑Safe Design – All wetted parts use compatible materials (copper, stainless steel, PTFE) with strict degreasing, eliminating ignition risks.
Energy Efficient – Low power consumption (3–11 kW / 4–15 hp) relative to output, reducing operating costs.
Compact & Reliable – Small footprint, few moving parts, low maintenance, and long service life for continuous duty.
Easy Integration – Designed to fit into existing cylinder filling lines, on‑site oxygen generation systems, or medical oxygen stations.
Wide Applications – Ideal for industrial oxygen cylinder filling, medical oxygen boosting, high‑pressure oxygen storage, and portable oxygen supply systems.
| Model | Inlet P (Mpa) | Outlet P (Mpa) | Capacity (Nm3/h) | Motor Power (kW) | Dimension L*W*H(mm) | Compression | Inlet size | Outlet Size | Weight (kg) |
| RVWN-20/5-25 | 0.5 | 2.5 | 20 | 3 | 1250*500*900 | 2 | Rc1/2 | Rc1/2 | 210 |
| RVWN-30/5-25 | 0.5 | 2.5 | 30 | 4 | 1250*550*900 | 2 | Rc1 | Rc1 | 230 |
| RVWN-40/5-25 | 0.5 | 2.5 | 40 | 5.5 | 1250*600*900 | 2 | Rc1 | Rc1 | 250 |
| RVWN-50/5-25 | 0.5 | 2.5 | 50 | 7.5 | 1250*600*900 | 2 | Rc1 | Rc1 | 270 |
| RVWN-60/5-25 | 0.5 | 2.5 | 60 | 7.5 | 1250*600*900 | 2 | Rc1 | Rc1 | 270 |
| RVWN-70/5-25 | 0.5 | 2.5 | 70 | 7.5 | 1250*600*900 | 2 | Rc1 | Rc1 | 270 |
| RVWN-80/5-25 | 0.5 | 2.5 | 80 | 11 | 1250*700*900 | 2 | Rc1 | Rc1 | 300 |
Applications
Industrial oxygen cylinder filling – Fills high-pressure oxygen cylinders for welding, cutting, and metal processing.
Medical oxygen stations – Boosts oxygen from concentrators or liquid tanks to cylinder pressure for hospital use.
On-site oxygen generation systems – Increases output pressure from PSA/VSA generators for storage or distribution.
High-pressure oxygen storage – Charges buffer tanks or cascade systems.
Portable oxygen supply – For field hospitals, emergency rescue, or remote sites.

1. Oxygen boosting requires special safety precautions. Our compressor is engineered with:
2. Strict degreasing – All components are cleaned to oxygen service standards.
3. Anti-static design – Prevents spark generation.
4. Low compression temperature – Multi-stage design with intercooling keeps temperatures safe.
5. Pressure relief valves – Overpressure protection on each stage.
6. Leak-tight seals – Minimizes oxygen leakage risk
✅ Plug-and-play – Skid-mounted or frame-mounted, ready to connect.
✅ Customizable – Flow, pressure, motor, cooling method can be tailored.
✅ Certifications available – CE, ISO 9001, ATEX (on request).
✅ Global support – Spare parts and technical assistance available worldwide.
The range covers seven model ratings in 10 Nm³/h increments. If demand changes during a shift, give Rocky the minimum and peak flow and the time spent at each. Ask which control arrangement suits that duty.
The estimate depends on cylinder water capacity, starting pressure, target pressure, the number of cylinders and the hours available. Include the oxygen flow available during filling so the estimate reflects both the booster and its gas supply.
The inlet accepts gaseous oxygen. A liquid oxygen installation needs a vaporizer upstream and a gaseous supply at the specified inlet conditions.
An actual-volume reading depends on the pressure and temperature at the meter. Provide those conditions and the meter’s reference settings so both flow figures can be compared on the same basis.
The published capacities apply at a 5 bar inlet. Send the lowest pressure measured while the station is drawing oxygen, together with the required flow, for a capacity assessment at that condition.
Specify the number of filling positions, cylinder valve connections and any manifold or hoses you need. Ask for these items to be identified separately in the quotation so you can match the package to your existing filling line.