A high-pressure oxygen booster system designed to take low-pressure oxygen (5 bar) and safely compress it to 30 bar, delivering a flow rate of 30 to 80 cubic meters per hour. Engineered with oxygen-compatible materials and oil‑free components to maintain gas purity and eliminate combustion risks. Ideal for industrial applications requiring reliable, on‑demand high‑pressure oxygen without cylinder handling.
| Model | Capacity (m3/h) | Inlet P (Barg) | Outlet P (Barg) | Motor Power (kW) | Compression | Dimensions L*W*H(mm) | Inlet Size | Outlet Size | Weight (kg) |
| VWN-30/5-50 | 30 | 5 | 50 | 4 | 2 | 1350*600*1200 | RC1" | RC1/2" | 320 |
| VWN-40/5-50 | 40 | 5 | 50 | 5.5 | 2 | 1350*600*1200 | RC1" | RC1/2" | 350 |
| VWN-50/5-50 | 50 | 5 | 50 | 7.5 | 2 | 1350*700*1200 | RC1" | RC1/2" | 380 |
| VWN-60/5-50 | 60 | 5 | 50 | 7.5 | 2 | 1350*700*1200 | RC1" | RC1/2" | 380 |
| VWN-70/5-50 | 70 | 5 | 50 | 11 | 2 | 1350*700*1200 | RC1" | RC1/2" | 380 |
| VWN-80/5-50 | 80 | 5 | 50 | 11 | 2 | 1350*700*1200 | RC1" | RC1/2" | 410 |
The VWN series offers six capacity options from 30 to 80 m³/h. This range supports industrial users with different oxygen consumption requirements.
The available capacities allow the system to serve multiple downstream consumers when their combined demand, operating pressure, and pipeline configuration remain within the selected model's rated performance.
Oxygen systems require careful control of materials, cleanliness, and contamination. The compressor uses oxygen-compatible materials and non-lubricated sealing components in the gas-contact system.
These design features help maintain the quality of the incoming oxygen. The booster itself does not increase oxygen purity; the purity of the delivered gas depends on the source and the cleanliness of the complete system.
The compressor uses two compression stages to increase oxygen pressure from 5 bar to 50 bar.
The two-stage arrangement distributes the pressure increase across the compression process. It is designed for the specified high-pressure operating range.
Oxygen compression requires careful temperature and pressure management. The design description includes temperature monitoring, controlled compression operation, and oxygen-service valve arrangements.
Suitable pressure protection and temperature monitoring should be incorporated into the complete installation to help operators identify abnormal operating conditions.
A PLC-based control system can be configured to manage compressor operation according to oxygen demand.
Depending on the selected control arrangement, automatic operation can coordinate motor or compression-stage operation to match system requirements. The control configuration should be confirmed when specifying the equipment.
When connected to an on-site oxygen source, such as a bulk liquid oxygen tank with a vaporizer or a plant oxygen pipeline, the booster can reduce dependence on transporting smaller supply cylinders to an external filling station.
This arrangement can simplify oxygen supply management. Cylinders being filled still require suitable handling, inspection, and filling procedures.
The compressor package is designed for industrial installation. Its skid-mounted structure, steel frame, and vibration-damping supports help provide a stable equipment base.
A protective enclosure can be included according to the selected configuration and installation environment.
The 50 bar oxygen booster is suitable for systems that require higher-pressure oxygen from an existing low-pressure source.
The compressor can supply high-pressure oxygen to compatible cylinder filling systems designed for a maximum operating pressure of 50 bar.
The filling manifold, cylinders, valves, and connecting pipelines must all be rated for the intended pressure. Cylinders requiring a final filling pressure above 50 bar need an additional compression stage or a different compressor configuration.
Oxygen is used as an assist gas in certain metal laser cutting processes, particularly when processing carbon steel.
The booster can support compatible systems requiring a high-pressure oxygen supply. Actual suitability depends on the laser equipment's pressure and flow requirements.
Some manufacturing processes require oxygen at pressures above those available from standard pipeline supplies. The booster can provide a higher-pressure source for compatible equipment and production systems.
Oxygen is used in selected oxidation reactions and chemical production processes. A high-pressure oxygen booster can supply the required gas pressure when the process design calls for a 50 bar source.
Certain wastewater treatment and oxidation systems use oxygen to support biological or chemical processes. The booster can serve compatible oxygen supply arrangements where increased pressure is required.
Research facilities may require controlled high-pressure oxygen for testing equipment, material experiments, and process evaluation. The selected model must match the required flow, pressure, and oxygen quality specifications.
Yes. The listed VWN series is designed for a 5 Barg inlet and a 50 Barg outlet. All six models use a two-stage compression arrangement.
No. Its rated outlet pressure is 50 bar, which is below the final filling pressure required by many standard high-pressure oxygen cylinders.
An additional high-pressure compression stage is required when the target filling pressure exceeds 50 bar.
No. An oxygen booster increases gas pressure; it does not generate or purify oxygen. The delivered oxygen quality depends on the inlet source and the cleanliness of all oxygen-contact components.
The listed configuration is designed for oxygen service. Do not switch to another gas without written confirmation from the manufacturer that the materials, seals, and complete gas path are suitable for that medium.
This depends on cylinder volume, initial pressure, target pressure, filling arrangement, and actual compressor flow. The model capacity alone cannot determine the number of cylinders that can be filled simultaneously.