| Availability: | |
|---|---|
| Quantity: | |
The ROCKY RWWN-30/5-50 Oil-Free Oxygen Booster Compressor is designed for applications requiring clean, stable, and pressurized oxygen. With a nominal inlet pressure of 5 bar and an outlet pressure of 50 bar, it delivers a rated flow of 30 Nm³/h through a three-stage compression system powered by a 5.5 kW motor.
Unlike conventional air compressors, this oxygen booster compressor uses an oil-free compression design and oxygen-compatible materials to minimize contamination risks. Its robust mechanical construction supports dependable operation while reducing routine maintenance requirements.
The compressor is suitable for oxygen supply systems, industrial gas processing, oxygen filling installations, and manufacturing processes requiring secondary oxygen pressurization.
The oil-free compression chamber eliminates the need for lubricating oil within the gas compression path. This design reduces the risk of hydrocarbon contamination and helps preserve the purity of the incoming oxygen.
Oxygen-compatible materials are used to address the specific requirements of oxygen service.
The compressor increases oxygen pressure from 5 bar to 50 bar, meeting the requirements of various medium- and high-pressure oxygen applications.
It provides secondary pressurization for oxygen supply networks, process equipment, and compatible gas storage systems.
The RWWN-30/5-50 adopts a three-stage compression configuration. Distributing compression across multiple stages helps manage thermal loads and reduce the mechanical stress associated with single-stage high-pressure compression.
A 5.5 kW motor drives the compressor to deliver a rated capacity of 30 Nm³/h. The matched motor and compression configuration support efficient operation under the specified working conditions.
The compressor features a durable structure designed to withstand the mechanical demands of oxygen pressurization. Its dimensions of 1350 × 600 × 1200 mm facilitate equipment layout planning and integration into industrial gas systems.
Oil-free gas compression removes the need for routine lubricating oil changes within the compression chamber. Regular maintenance primarily involves inspecting seals, filters, valves, and other serviceable components.
Consistent oxygen pressure and flow help minimize interruptions in oxygen-dependent processes. The compressor supports production stability when integrated with a properly sized oxygen source and downstream distribution system.
| Model | Inlet P (Mpa) | Outlet P (Mpa) | Capacity(m3/h) | Motor Power(Kw) | Dimension L*W*H(mm) | Compression | Inlet size | Outlet Size | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| RVWN-20/5-50 | 0.5 | 5 | 20 | 4 | 1250x550x900 | 2 | Rc1/2 | Rc1/2 | 230 |
| RWWN-30/5-50 | 0.5 | 5 | 30 | 5.5 | 1350x600x1200 | 3 | Rc1 | Rc1/2 | 320 |
| RWWN-40/5-50 | 0.5 | 5 | 40 | 7.5 | 1350x600x1200 | 3 | Rc1 | Rc1/2 | 350 |
| RWWN-50/5-50 | 0.5 | 5 | 50 | 11 | 1350x700x1200 | 3 | Rc1 | Rc1/2 | 380 |
| RWWN-60/5-50 | 0.5 | 5 | 60 | 11 | 1350x700x1200 | 3 | Rc1 | Rc1/2 | 380 |
| RWWN-70/5-50 | 0.5 | 5 | 70 | 11 | 1350x700x1200 | 3 | Rc1 | Rc1/2 | 380 |
| RWWN-80/5-50 | 0.5 | 5 | 80 | 15 | 1350x700x1200 | 3 | Rc1 | Rc1/2 | 410 |
| RSWN-100/5-50 | 0.5 | 5 | 100 | 15 | 1500x800x1250 | 2 | Rc1 | Rc1/2 | 480 |
The ROCKY oxygen booster compressor series covers rated capacities from 20 to 100 Nm³/h, with motor power ranging from 4 to 15 kW. Different models accommodate varying oxygen consumption and production capacity requirements.
Oxygen enters the booster compressor from an external oxygen supply system. A stable inlet pressure of approximately 5 bar supports the rated compression performance.
The reciprocating compression system progressively increases oxygen pressure across three stages. Multi-stage compression distributes the pressure increase across the compression process and helps manage compression heat.
The gas compression path operates without lubricating oil. This arrangement minimizes the introduction of oil contaminants during oxygen pressurization.
Compressed oxygen is discharged at the rated outlet pressure of 50 bar. The pressurized gas can then enter compatible storage vessels, distribution pipelines, or downstream process equipment.
The oil-free oxygen booster compressor can support oxygen pressurization within medical oxygen infrastructure where the complete system satisfies applicable medical gas purity, equipment, and regulatory requirements.
Industrial oxygen is widely used in oxy-fuel cutting, welding, and certain laser cutting processes. The compressor provides secondary pressurization for oxygen distribution systems serving compatible metal processing equipment.
Specialized oxygen supply projects may require clean and pressurized oxygen for gas storage and distribution. Aerospace and submarine life-support applications require project-specific engineering, equipment qualification, and regulatory approval.
Oxygen is used in wastewater treatment, biological oxidation, and ozone generation systems. An oxygen booster can support upstream storage and gas distribution where secondary pressurization is required.
Many chemical manufacturing processes use oxygen to support controlled oxidation reactions. Stable oxygen delivery helps maintain consistent gas availability for compatible processing equipment.
The 50 bar oxygen filling compressor supports gas transfer and filling applications within its rated discharge pressure.
It can be integrated into compatible oxygen storage and distribution systems that do not require filling pressures above 50 bar.
The incoming oxygen should meet the cleanliness, purity, and moisture requirements specified for the compressor and intended application. Oil, grease, particles, and other incompatible contaminants must be excluded from oxygen service.
The compressor is designed around a nominal inlet pressure of 5 bar. Significant pressure fluctuations may affect discharge performance and available flow capacity.
The upstream oxygen supply should be sized to meet the compressor's gas demand.
Install the oxygen booster compressor in a suitable, adequately ventilated equipment area. The installation layout should provide sufficient access for inspection, maintenance, and heat dissipation.
All connected pipelines, valves, pressure vessels, and safety devices must be suitable for oxygen service and the applicable operating pressure.
Installation and commissioning should be performed by qualified personnel following the manufacturer's instructions and relevant safety requirements.
Regularly inspect seals, filters, valves, gas connections, and other serviceable components according to the recommended maintenance schedule.
Timely replacement of worn components helps maintain compression performance and reduce unnecessary downtime.
Oxygen-enriched environments can increase combustion risks. Gas-contact components must remain free from oil, grease, and other combustible contaminants.
Use only cleaning methods and replacement components approved for the equipment's oxygen service requirements.
Monitor inlet pressure, discharge pressure, operating temperature, and equipment condition during service. Abnormal pressure changes, unusual noise, excessive temperature, or suspected leakage require appropriate inspection.
Maintenance involving pressurized oxygen equipment must be carried out by qualified technicians. Follow the manufacturer's isolation, depressurization, and servicing procedures before undertaking maintenance.
Selecting an oxygen booster compressor requires matching the equipment to the actual oxygen demand, operating pressure, and intended application.
| Selection Factor | Key Consideration |
|---|---|
| Oxygen Flow Rate | Match rated compressor capacity to downstream oxygen consumption. |
| Inlet Pressure | Evaluate the pressure and capacity of the existing oxygen source. |
| Outlet Pressure | Select a compressor suitable for the required downstream pressure. |
| Motor Power | Consider electrical supply requirements and operating costs. |
| Oxygen Purity | Match gas cleanliness and purity requirements to the application. |
| Operating Schedule | Evaluate daily operating hours and expected duty cycle. |
| Installation Space | Allow adequate space for equipment, ventilation, and maintenance. |
| Industry Requirements | Consider applicable equipment qualification and regulatory requirements. |
The RWWN-30/5-50 is designed for projects requiring a rated oxygen capacity of 30 Nm³/h at a discharge pressure of 50 bar. For higher oxygen consumption, ROCKY offers alternative models with capacities of up to 100 Nm³/h within this product series.
The compressor uses oil-free compression and oxygen-compatible materials to reduce contamination and ignition risks. Safe operation also depends on proper installation, oxygen cleanliness, maintenance, and compliance with applicable safety requirements.
No. This model is configured specifically for oxygen service. Compressors for nitrogen, hydrogen, or other gases require gas-specific configurations and material compatibility assessments.
Yes. Although the gas compression chamber does not require lubricating oil changes, seals, filters, valves, and other components require periodic inspection and servicing.
A significant reduction in inlet pressure may decrease the available discharge flow and affect compression performance. A stable oxygen source is important for maintaining rated operating conditions.
No. This model has a rated discharge pressure of 50 bar. Oxygen cylinders requiring 150 bar or 200 bar filling pressure need appropriately rated oxygen compression equipment.
Yes, provided that the generator's outlet pressure, oxygen flow, gas purity, and supply characteristics are compatible with the booster compressor's operating requirements.
No. An oxygen booster compressor increases gas pressure rather than oxygen concentration. Oxygen purity primarily depends on the upstream oxygen generation or purification system.
Pricing depends on the required flow capacity, discharge pressure, motor configuration, system integration, application requirements, and order quantity.
Provide the required oxygen flow rate, inlet pressure, discharge pressure, gas purity, electrical supply, operating schedule, and intended application. These details help identify a suitable compressor configuration.
Looking for reliable oil-free oxygen compression? Share your oxygen flow, pressure, and application requirements with ROCKY. Our team can help you select a suitable compressor for your project.