| Availability: | |
|---|---|
| Quantity: | |
The 90–132 kW low pressure screw air compressor provides a direct compressed air supply for industrial equipment operating at 2–5 bar. It is designed for facilities that consume large volumes of air but do not require conventional 7–10 bar compressor output.
The system combines a permanent magnet motor, variable frequency drive, and two-stage screw compression. The PM VSD system adjusts motor speed according to changing air demand. This helps reduce unnecessary power consumption during partial-load operation.
The RL125APM, RL150APM, and RL175APM models cover different airflow requirements. Each model offers four working pressure options, allowing users to select a configuration based on actual process demand.
| Low-pressure PM VSD Screw air compressor | |||||||
| Model | Air Delivery (m3/min) | Working pressure (bar) | Power (kW/hp) | Noise dB(A) | Outlet diameter | Dimensions (mm) | Weight (kg) |
| L * W * H | |||||||
| RL125APM | 34.0 | 2 | 90/125 | 76 | DN125 | 3000*1900*1950 | 3500 |
| 28.0 | 3 | 90/125 | 76 | DN100 | 2500*1650*1900 | 3100 | |
| 24.0 | 4 | 90/125 | 76 | DN100 | 2500*1650*1900 | 3000 | |
| 20.0 | 5 | 90/125 | 76 | DN80 | 2500*1650*1900 | 2950 | |
| RL150APM | 43.0 | 2 | 110/150 | 76 | DN200 | 3600*2200*2200 | 5300 |
| 34.0 | 3 | 110/150 | 76 | DN125 | 3000*1900*1950 | 4000 | |
| 29.6 | 4 | 110/150 | 76 | DN100 | 3000*1900*1950 | 3500 | |
| 24.0 | 5 | 110/150 | 76 | DN80 | 3000*1900*1950 | 3200 | |
| RL175APM | 52.0 | 2 | 132/175 | 76 | DN200 | 3600*2200*2200 | 5800 |
| 42.0 | 3 | 132/175 | 76 | DN125 | 3000*1900*1950 | 4300 | |
| 36.5 | 4 | 132/175 | 76 | DN100 | 3000*1900*1950 | 4100 | |
| 30.5 | 5 | 132/175 | 76 | DN80 | 3000*1900*1950 | 3700 | |
The compressor delivers air directly within the 2–5 bar working pressure range. This avoids unnecessary high-pressure compression when the production process only requires low-pressure air.
It is suitable for facilities with high-volume, low-pressure air consumption.
The permanent magnet motor works with a variable frequency drive to adjust operating speed according to air demand.
This arrangement helps reduce unloading losses and unnecessary energy consumption during changing production loads.
The compressor uses a two-stage compression arrangement optimized for low-pressure output. The internal compression stages and final discharge pressure describe different aspects of the machine.
The design distributes compression across two stages to support the required airflow and pressure range.
Variable-speed control helps the compressor respond to changing air consumption. Proper model selection and system configuration support stable pressure delivery to production equipment.
The series offers airflow from 20 to 52 m³/min, depending on motor power and working pressure.
This capacity range supports large industrial air networks and equipment operating simultaneously.
The published noise level is 76 dB(A) across the listed configurations. Proper installation and equipment placement should be considered when planning the compressor room.
Low-pressure compressed air is used in production processes that require continuous airflow without unnecessarily high discharge pressure.
Air-jet looms require a consistent compressed air supply for yarn insertion and weaving operations. Low-pressure compressors can support textile production lines with high air consumption.
Battery manufacturing processes use compressed air in electrode coating, drying, material handling, and pneumatic equipment. The appropriate air treatment system should be selected according to process cleanliness requirements.
Compressed air supports powder conveying, pneumatic transport, fermentation-related equipment, and other production processes. Air quality requirements depend on the specific application.
Typical applications include bottling equipment, fermentation systems, pneumatic packaging, and automated production lines.
Additional filtration and drying equipment may be required where product-contact air quality is critical.
The compressor can supply low-pressure air to compatible pneumatic equipment and plastics production processes, including applications involving blow molding.
A: This can be confusing. It typically means the compressor uses a two-stage compression mechanism (for high efficiency) but is specifically designed and sold as a unit for single, low-pressure output applications. The "two-stage" describes the internal process, while "single-stage low-pressure" describes its application output.
A: Standard compressors are inefficient for low-pressure use because they produce high-pressure air (e.g., 8-10 bar) and then waste energy by throttling it down. This machine is engineered from the ground up to produce only the low pressure you need, eliminating that waste.
A: Absolutely. For facilities with high air consumption at low pressure, the massive energy savings typically lead to a Return on Investment (ROI) in 1-3 years. The compressor pays for itself through lower electricity bills.
A: You need two key pieces of information:
(1) Your exact required working pressure (in bar)and
(2) Your facility's maximum air consumption (in m³/min or cfm).
A compressed air audit is often recommended to determine this accurately.
The published noise level for the listed RL125APM, RL150APM, and RL175APM configurations is 76 dB(A). Actual noise measurements may vary with installation conditions and the measurement method.