| Availability: | |
|---|---|
| Quantity: | |
The ROCKY 150 Bar Oil-Free Oxygen Booster Compressor is designed to increase oxygen pressure for storage, cylinder filling, and industrial gas supply. Its oil-free compression design helps maintain incoming oxygen quality without introducing lubricating oil contamination during pressurization.
The RWWY series includes eight models with a rated inlet pressure of 4 barg, an outlet pressure of 150 barg, and capacities ranging from 5 to 40 m³/h. Motor power ratings from 4 to 15 kW provide different equipment options to accommodate varying oxygen consumption and production requirements.
The compressor supports applications in chemical processing, metal cutting, food processing, scientific research, air separation, and appropriately qualified medical oxygen supply systems.
The compact equipment layout reduces installation space requirements, making the oxygen booster suitable for small and medium-sized oxygen production facilities. Its integrated structure also facilitates equipment installation, inspection, and routine maintenance.
The oil-free compression system prevents lubricating oil from entering the oxygen compression chamber. This helps maintain incoming oxygen purity without introducing secondary lubricating oil contamination during pressurization.
The high-pressure oxygen booster compressor delivers oxygen at a rated outlet pressure of 150 barg. It meets the pressure requirements of compatible cylinder filling systems and industrial high-pressure oxygen supply applications.
The compressor is designed for smooth operation with reduced mechanical noise and vibration. Its stable operating characteristics make it suitable for industrial facilities and indoor equipment rooms with appropriate ventilation and installation conditions.
Designed for continuous-duty applications, the compressor supports extended operating periods under specified operating conditions. Its construction helps maintain a consistent oxygen supply while reducing unnecessary production interruptions.
The PLC-based control system monitors operating conditions and provides pressure and temperature alarms. Automated monitoring helps operators identify abnormal conditions and manage the oxygen compression process more efficiently.
Oxygen-contact components use materials selected for oxygen service. Appropriate cleaning procedures help minimize contamination and reduce risks associated with high-pressure oxygen compression.
| Model | Capacity (m³/h) | Inlet P (barg) | Outlet P (barg) | Motor Power (kW) | Rotating Speed (rpm) | Inlet Size | Outlet Size | Dimensions L×W×H (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| RWWY(1-5)4-150 | 5 | 4 | 150 | 4.0 | 470 | RC1/2" | G5/8 | 1350×850×1100 | 380 |
| RWWY-10/4-150 | 10 | 4 | 150 | 5.5 | 470 | RC1/2" | G5/8 | 1350×1050×1100 | 410 |
| RWWY-15/4-150 | 15 | 4 | 150 | 7.5 | 640 | RC1/2" | G5/8 | 1350×1050×1100 | 420 |
| RWWY-20/4-150 | 20 | 4 | 150 | 11 | 580 | RC1/2" | G5/8 | 1350×1050×1100 | 430 |
| RWWY-25/4-150 | 25 | 4 | 150 | 11 | 640 | RC1/2" | G5/8 | 1350×1050×1100 | 430 |
| RWWY-30/4-150 | 30 | 4 | 150 | 15 | 470 | RC1/2" | G5/8 | 1350×1050×1100 | 450 |
| RWWY-35/4-150 | 35 | 4 | 150 | 15 | 470 | RC1/2" | G5/8 | 1350×1050×1100 | 450 |
| RWWY-40/4-150 | 40 | 4 | 150 | 15 | 580 | RC1/2" | G5/8 | 1350×1050×1100 | 450 |
The oil-free oxygen booster compressor receives low-pressure oxygen from an external oxygen supply system. The gas enters the compression chamber, where its pressure increases through mechanical compression without introducing lubricating oil into the oxygen stream.
During operation, the PLC control system monitors pressure and temperature conditions. The compressed oxygen is then delivered through the high-pressure outlet to compatible storage, cylinder filling, or industrial gas distribution systems.
The oxygen booster increases gas pressure rather than generating or purifying oxygen. Its performance depends on the incoming oxygen supply, operating conditions, and downstream system configuration.
The 150 Bar oxygen booster compressor is designed for integration into compatible oxygen cylinder filling stations. It pressurizes oxygen supplied by an external generation system for storage and subsequent distribution.
The compressor can support oxygen pressurization and storage within appropriately qualified medical oxygen supply systems. Medical applications require suitable oxygen quality, system validation, and compliance with applicable regulatory requirements.
Chemical production facilities use high-pressure oxygen for various oxidation and process gas applications. Oil-free compression helps prevent lubricating oil contamination in oxygen-sensitive production processes.
High-pressure oxygen can be stored and supplied to compatible oxygen distribution systems for oxy-fuel cutting and other metal processing applications. Downstream pressure regulation provides the operating pressure required by individual processing equipment.
Oil-free oxygen compression supports food processing applications that require controlled oxygen supplies. Gas quality and equipment configuration must satisfy the relevant food processing requirements.
Laboratories and research facilities may require pressurized oxygen for experimental equipment, material testing, and controlled reaction processes. The available capacity options accommodate different oxygen consumption requirements.
The oxygen booster compressor can be integrated with air separation equipment to increase the pressure of generated oxygen. This supports oxygen storage, transportation, and downstream industrial applications.
High-pressure oxygen service requires careful attention to material compatibility, equipment cleanliness, operating temperature, and system design. The ROCKY oxygen booster compressor combines oil-free compression with oxygen-compatible construction and intelligent monitoring to support controlled operation.
| Safety Feature | Function |
|---|---|
| Oil-Free Compression | Prevents lubricating oil from entering the compressed oxygen stream. |
| Oxygen-Compatible Materials | Reduces risks associated with incompatible oxygen-contact materials. |
| Component Cleaning | Minimizes contaminants within oxygen-contact components. |
| Pressure Monitoring | Monitors operating pressure and provides abnormal pressure alarms. |
| Temperature Monitoring | Helps identify abnormal temperature conditions during compression. |
| PLC Control System | Supports automated equipment monitoring and operation. |
The compressor should be integrated with oxygen-compatible piping, valves, pressure protection devices, and downstream equipment rated for the intended operating conditions.
Selecting the right oil-free oxygen booster compressor depends on the required oxygen capacity, supply pressure, discharge pressure, and installation conditions. The ROCKY RWWY series offers eight models with capacities ranging from 5 to 40 m³/h, accommodating different oxygen supply requirements.
Select the compressor capacity according to actual oxygen consumption and production requirements. The upstream oxygen supply system should provide sufficient gas flow to support the selected compressor.
The RWWY series features a rated inlet pressure of 4 barg and an outlet pressure of 150 barg. Proper matching between the oxygen source, compressor, and downstream equipment is essential for stable operation.
The available models feature motor power ratings from 4 to 15 kW. Equipment selection should consider the required oxygen capacity, electrical supply, and expected operating conditions.
Equipment dimensions, ventilation, maintenance access, and oxygen-compatible piping should be considered during installation planning. The installation environment should meet the requirements for high-pressure oxygen equipment.
Regular inspection and preventive maintenance help maintain the operating performance of the oil-free oxygen booster compressor. Operators should monitor pressure, temperature, operating noise, and vibration to identify abnormal operating conditions.
Maintaining the cleanliness of oxygen-contact components is particularly important in high-pressure oxygen systems. Inspection intervals, component replacement, and maintenance procedures should follow the manufacturer's operating instructions and applicable oxygen-service requirements. All maintenance should be performed by qualified personnel.
Yes. The compressor can be integrated with a PSA oxygen generator when the oxygen purity, supply capacity, inlet pressure, and system configuration meet the compressor's operating requirements.
No. An oxygen booster increases gas pressure rather than oxygen purity. Oil-free compression helps maintain the incoming oxygen quality by preventing lubricating oil contamination.
An oxygen generator separates oxygen from ambient air, while an oxygen booster increases the pressure of an existing oxygen supply. Both devices can work together in an oxygen production and filling system.
The standard compressor is rated for a discharge pressure of 150 barg. Applications requiring higher filling pressures need a compressor and filling system specifically designed and rated for those pressures.
Filling time depends on compressor capacity, cylinder volume, initial cylinder pressure, target pressure, gas temperature, and the configuration of the filling system.
Parallel compressor configurations can be considered for applications requiring increased oxygen capacity or operational flexibility. The configuration requires compatible control, piping, and pressure protection systems.
Customers should provide the required oxygen capacity, inlet pressure, discharge pressure, oxygen purity, power supply, intended application, and expected operating schedule. This information helps determine the appropriate compressor configuration.
ROCKY offers eight 150 Bar oil-free oxygen booster compressor models with capacities ranging from 5 to 40 m³/h for cylinder filling, industrial gas supply, and air separation systems.
Share your required oxygen capacity, inlet pressure, discharge pressure, and application details with our team for equipment selection and a tailored quotation.