You are here: Home » Products » Oil Free Air Compressor » Oil-Free Water-Lubricated Screw Air Compressor » 150–175 HP Class 0 Water-Lubricated Oil-Free Screw Air Compressor

150–175 HP Class 0 Water-Lubricated Oil-Free Screw Air Compressor

1.Air delivery: 15.56~23.1m3/min 549~815cfm
2. Pressure: 0.7~1.25 MPa/7~12.5 bar/101.5~182 psi
3. Power: 110~132 kW/150~175 hp
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Oil-free water-lubricated screw air compressor adopts high-performance permanent magnet synchronous motor and variable frequency speed regulation technology. The compression chamber is completely oil-free and uses treated pure water as lubrication, cooling and sealing medium to replace the lubricating oil in traditional air compressors.


Technical Parameters


Oil-free Water Lubricated Screw Air Compressor RW Series
Model Air Delivery (m3/min) Power (kW) Lubricating water amount (Liters) Cooling water amount T/Hour Cooling water inlet/outlet diameter Noise dB(A) Outlet diameter Dimension (mm) Weight (Kg)
8 bar 10 Bar 12.5 bar L*W*H
RW-110A/W 19.85 16.66 15.56 110 180 24.0 2" 78 2 1/2" 3000*1700*2250(A) 2200*1500*1800(W) 3150(A) 2460(W)
RW-132A/W 23.10 19.97 16.90 132 240 30.0 2" 78 2 1/2" 3000*1700*2250(A) 2200*1500*1800(W) 3500(A) 2500(W)


Key Features and Advantages


·Water-Lubricated Oil-Free Compression

The compression chamber uses treated water instead of lubricating oil. Water provides lubrication, cooling, and sealing during the compression process.

This design prevents conventional lubricating oil from being injected into the compressed air through the compression chamber. It is suitable for applications where oil contamination needs strict control.


·Class 0 Air Quality

The RW series is positioned for Class 0 oil-free compressed air applications.

ISO 8573-1 Class 0 requires an agreed contamination limit that is more stringent than Class 1. The applicable test report should identify the specified contaminant and measured performance.

The Class 0 oil designation does not automatically establish particle or moisture purity. These parameters require separate specifications and suitable air treatment.


·Permanent Magnet Motor

The permanent magnet synchronous motor provides the driving power for the compressor.

Compared with conventional motor arrangements, PM technology can offer improved motor efficiency, particularly when correctly matched with variable-speed control.


·Variable Frequency Control

The VFD adjusts motor speed according to compressed air demand.

When production loads change, the compressor can regulate its operating speed instead of relying entirely on fixed-speed operation. This helps reduce unnecessary energy consumption under suitable load conditions.

Actual energy savings depend on operating hours, load profile, system pressure, and the performance of the existing compressor installation.


·Water Cooling and Heat Management

Water performs the cooling function inside the compression chamber. The compressor also offers different overall cooling configurations.

Air-cooled and water-cooled versions allow users to select a suitable arrangement according to cooling water availability, ventilation, installation space, and factory utilities.


·Reduced Mechanical Wear

The water-lubricated compression design helps reduce friction between components intended for water lubrication.

Proper water treatment and circulation are important for maintaining the compression system. Regular inspection helps prevent scaling, deposits, and other water-related operating problems.


·Controlled Operating Noise

The listed noise level is 78 dB(A). The water medium supports the compressor's operating and cooling design.

Actual sound levels at the installation site can vary with room acoustics, equipment arrangement, and measurement conditions.



Industrial Applications

The RW water-lubricated oil-free screw air compressor is intended for medium and large industrial facilities where compressed air contamination must be carefully controlled.


Pharmaceutical Industry

Pharmaceutical manufacturing uses compressed air in API production, sterile preparation, fermentation aeration, and laboratory operations.

Oil-free compressed air helps reduce the risk of oil contamination in production processes. The complete compressed air system must also meet the applicable GMP, filtration, drying, and validation requirements.


Food and Beverage

Food and beverage production uses compressed air in processing, packaging, filling, and fermentation.

For applications involving direct contact with products or packaging, air purity requirements should be specified according to the process and relevant food safety standards.

The water-lubricated compressor can serve as part of a properly designed compressed air treatment system.


Electronics and Semiconductors

Electronics manufacturing requires controlled compressed air for precision cleaning, component processing, and production equipment.

Applications include:

  • Semiconductor manufacturing.

  • Flat panel display production.

  • PCB precision cleaning.

  • Photovoltaic material production.

Suitable particle filtration and moisture control remain important for sensitive manufacturing processes.


Chemical and Materials Processing

Chemical and material production may require compressed air for chemical synthesis, precision spray coating, and process equipment.

Other applications include textile and chemical fiber manufacturing, where oil contamination can affect production quality or equipment performance.

The required compressed air quality depends on the specific process.


Medical and Central Air Supply

Hospitals and medical facilities use compressed air for equipment operation and selected medical gas applications.

The RW series may be considered as a compressor component within an appropriately engineered central compressed air system.

However, a Class 0 oil-free compressor alone does not establish compliance with medical breathing air requirements. Medical air systems require additional treatment, monitoring, redundancy, testing, and compliance with applicable medical gas standards.


Frequently Asked Questions


Q1. What does Class 0 mean for an oil-free screw air compressor?

Class 0 is an ISO 8573-1 compressed air purity classification with limits defined by the equipment supplier or user. These limits must be more stringent than Class 1 for the specified contaminant.

Class 0 does not mean that compressed air contains absolutely no particles, water, or other contaminants. The applicable contaminant category and agreed limits should be documented.


Q2. Does a water-lubricated compressor require oil changes?

The compression chamber uses treated water instead of lubricating oil for lubrication, cooling, and sealing.

However, the complete machine may contain mechanical components with separate lubrication requirements. Follow the manufacturer's instructions for all designated service points.


Q3. Can ordinary tap water be used as the lubricating medium?

Do not assume that untreated tap water is suitable.

The compressor requires treated water that meets the manufacturer's specifications. Incorrect water quality can cause scaling, corrosion, deposits, or circulation problems.


Q4. Does Class 0 mean no air dryer or filter is needed?

No. Class 0 oil purity does not automatically establish particle or moisture purity.

Air dryers and filters may still be required to achieve the specified pressure dew point and particle concentration. The treatment system should be selected according to the complete compressed air quality specification.


Q5. Can the compressor operate at different pressure settings?

The RW series offers 8, 10, and 12.5 bar configurations. The required configuration should be selected according to the application and the model's rated airflow.

Do not assume that every pressure setting can be changed freely during operation without confirming the equipment configuration.


Q6. What happens if the lubricating water circulation stops?

Insufficient water circulation can affect lubrication, cooling, and sealing inside the compression chamber.

Stop the equipment according to the operating procedure and inspect the water supply, circulation pump, filters, and protection system before restarting.

Previous: 
Next: 

Quick Links

Products

Contact Us

Telephone: +86-173-2106-2761
 WhatsApp: +8617321062761
Email:  Anna@rockymachinery.com
 Address: Room 604, #12, Powerlong Center, No.689 Xiwang Road, Jiading District, Shanghai, China
Leave Us A Message
Copyright © 2025 Shanghai Rocky Machinery Co., Ltd. All Rights Reserved.   沪ICP备2021037284号-2