The RKM Series is an oil-injected rotary screw compressor for industrial compressed air systems. Air is compressed in a single screw stage driven by a permanent magnet synchronous motor. A variable frequency drive responds to changes in air use by adjusting motor speed within the compressor’s operating range. This is useful on production lines where several machines share an air header and demand rises and falls during a shift. The series includes both air-cooled and water-cooled packages, so the same selection process can start with airflow and pressure before moving to the utilities each package needs.
When replacing an existing compressor, use measured air demand if available. An old motor rating can help identify the equipment, but it does not show how much air the line actually uses. The model table gives delivery ranges, outlet sizes, dimensions, and weights so buyers can check both output and installation fit.
The inverter changes motor speed as demand shifts. When fewer machines draw from the header, the drive can reduce output instead of holding full speed. When demand picks up, the drive raises speed within its operating range to help hold pressure near the setpoint. Pressure at the end of a production line also depends on the pipework, filters, and dryer. If the line is sensitive to pressure changes, check pressure at the equipment during peak use as well as at the compressor discharge.
APM models release heat to room air. They suit sites with enough ventilation to move warm discharge air away from the compressor intake. When planning the room, account for other heat sources and keep cooling air paths clear.
WPM models transfer heat to a cooling-water circuit. They are an option for plants with a suitable water loop and for long shifts or warm compressor rooms where ventilation alone is difficult to manage. Allow space for supply and return piping and access to the water connections.
At the same motor rating, the RK420 APM and WPM models have identical listed air delivery across all three pressures. The same applies to the RK475 pair. The WPM versions are 400 mm shorter and 300 kg lighter in both pairs. The two RK420 versions are listed at 82 dB(A). For the RK475, the air-cooled model is listed at 85 dB(A) and the water-cooled model at 82 dB(A).
Read the air delivery range in the column for your working pressure. Use the rest of the row to check power, outlet size, cabinet dimensions, weight, and noise for that model.
Intelligent PM VSD Screw Air Compressor
| Intelligent PM VSD Screw Air Compressor | ||||||||
| Model | Air Delivery (m3/min) | Power (kW/hp) | Noise dB(A) | Outlet diameter | Dimensions (mm) | Weight (kg) | ||
| 8 bar | 10 bar | 13 bar | L * W * H | |||||
| RK10APM | 0.5-1.2 | 0.4-1.0 | 0.3-0.7 | 7.5/10 | 63 | G3/4 | 700*600*860 | 180 |
| RK15APM | 0.6-1.7 | 0.5-1.6 | 0.4-1.0 | 11/15 | 65 | G3/4 | 1000*750*1070 | 300 |
| RK20APM | 1.0-2.4 | 0.8-2.1 | 0.7-1.6 | 15/20 | 65 | G3/4 | 1000*750*1070 | 320 |
| RK30APM | 1.5-3.7 | 1.3-3.2 | 1.1-2.8 | 22/30 | 68 | G1 | 1350*850*1120 | 430 |
| RK40APM | 2.0-5.0 | 1.6-3.9 | 1.4-3.4 | 30/40 | 68 | G1 | 1350*800*1110 | 460 |
| RK50APM | 2.5-6.2 | 2.2-5.6 | 2.0-4.9 | 37/50 | 69 | G1 1/2 | 1500*1000*1350 | 650 |
| RK60APM | 3.0-7.3 | 2.4-6.0 | 2.3-5.9 | 45/60 | 70 | G1 1/2 | 1500*1000*1350 | 730 |
| RK75APM | 3.8-9.5 | 3.5-8.7 | 3.0-7.3 | 55/75 | 70 | G2 | 1700*1220*1550 | 950 |
| RK100APM | 5.1-12.8 | 4.5-11.3 | 3.7-9.2 | 75/100 | 72 | G2 | 1700*1200*1550 | 1050 |
| RK125APM | 6.2-15.5 | 5.4-13.6 | 5.0-12.5 | 90/125 | 72 | G2 | 2100*1400*1650 | 1420 |
| RK150APM | 7.8-19.6 | 7.1-17.8 | 6.2-15.5 | 110/150 | 72 | DN65 | 2500*1650*1900 | 2200 |
| RK175APM | 9.3-23.2 | 7.8-19.5 | 7.1-17.8 | 132/175 | 72 | DN65 | 2500*1650*1900 | 2400 |
| RK220APM | 11.1-27.8 | 9.2-23.0 | 8.0-20.0 | 160/220 | 72 | DN80 | 3000*1900*1950 | 3650 |
| RK250APM | 12.5-31.2 | 11.0-27.5 | 10.3-25.8 | 185/250 | 72 | DN80 | 3000*1900*1950 | 3950 |
| RK275APM | 13.6-34.0 | 12.2-30.5 | 11.2-28.0 | 200/275 | 76 | DN80 | 3000*1900*1950 | 4200 |
| RK300APM | 14.0-35.0 | 12.8-32.0 | 12.0-30.0 | 220/300 | 76 | DN100 | 3600*2200*2200 | 4600 |
| RK350APM | 16.6-41.5 | 15.2-38.0 | 14.0-34.9 | 250/350 | 76 | DN100 | 3600*2200*2200 | 5900 |
| RK375APM | 20.2-50.6 | 18.4-46.0 | 16.6-41.5 | 280/375 | 82 | DN100 | 3600*2200*2200 | 6000 |
| RK420APM | 22.2-55.9 | 20.0-50.1 | 16.8-42.0 | 315/420 | 82 | DN125 | 4600*2300*2430 | 7800 |
| RK420WPM | 22.2-55.9 | 20.0-50.1 | 16.8-42.0 | 315/420 | 82 | DN125 | 4200*2300*2430 | 7500 |
| RK475APM | 26.0-65.4 | 22.0-55.1 | 18.4-46.0 | 355/475 | 85 | DN125 | 4600*2300*2430 | 8200 |
| RK475WPM | 26.0-65.4 | 22.0-55.1 | 18.4-46.0 | 355/475 | 82 | DN125 | 4200*2300*2430 | 7900 |
Start with the lowest pressure the most demanding machine needs. Allow for pressure drop through pipework and any compressed air treatment equipment. Next, compare your sustained peak and typical low-demand airflow with the model’s delivery range at that pressure. Check both ends of the range if the plant runs different staffing levels or equipment schedules across shifts.
For example, the 37 kW RK50APM delivers 2.5–6.2 m³/min at 8 bar and 2.2–5.6 m³/min at 10 bar. A process that needs 6.0 m³/min at 10 bar exceeds that model’s listed output. Once the airflow fits, check the available electrical supply, delivery route, service clearances, and outlet connection.
RKM compressors can supply plant air for pneumatic fixtures in machining, general equipment in electronics and semiconductor facilities, and production machinery in chemical, textile, and injection molding plants. For continuous production, assess the expected load across shifts and whether a standby air supply is needed during planned service. In food and pharmaceutical facilities, identify utility-air uses separately from any process with a specified oil limit or direct product contact. If the process specification calls for oil-free compression, consider Rocky’s oil-free compressor range.
Before replacing a fixed-speed unit, log compressor power and system pressure across a representative production cycle, including idle periods and shift changes. Use the same working pressure and delivered airflow when comparing the existing setup with an RKM model. Where water cooling is under consideration, include the energy used by any dedicated pumps or cooling equipment in the comparison. Rocky’s variable speed screw compressors offer further options if the project calls for a different configuration.
The screw element and bearings are designed for long service. Plan access around the enclosure before placing the machine. Leave room to open the panels and remove service parts without moving piping or other equipment. For a plant that operates around the clock, use the model’s service schedule to plan maintenance windows and check which parts should be stocked on site.
It depends on the demand profile. A fixed-speed unit that spends many hours running unloaded offers more scope for savings than one that stays near full load. When demand drops below the RKM model’s minimum delivery, check how the controls manage that low-demand period.
Yes, if the loop can supply the selected model’s required flow, inlet temperature, and water quality. If there is no suitable loop, evaluate a cooling tower or a heat exchanger connected to a separate heat rejection system.
Follow the model’s service intervals for the air filter, oil filter, and lubricant. On water-cooled packages, also inspect the cooling-water circuit for scale and check freeze protection where required.
An optional monitoring system can provide remote access by phone or computer to pressure, temperature, and energy-use readings. Specify remote monitoring when requesting a quote.
It can be considered for trim duty, with the fixed-speed unit covering base demand. Check the control sequence and pressure settings so the two compressors respond to demand in the intended order.
Receiver size depends on how large and how frequent the short demand peaks are. A receiver near an intermittent high-demand machine can help cover brief bursts and reduce pressure dips.
The selected model, cooling option, and scope of supply all affect the quote. Specify whether the price should cover the compressor alone or also include a receiver, dryer, filters, or remote monitoring.
Send Rocky your operating pressure, minimum and peak airflow, and preferred cooling method. Include any space or utility limits so the quote can reflect your installation.